KCD2-UT2-Ex1 通用温度转换器现货供应

KCD2-UT2-Ex1 通用温度转换器现货供应

       倍加福通用温度转换器KCD2-UT2-Ex1,单通道隔离栅,24 V DC电源,Fuxb automation will serve you wholeheartedly! +86-021-51601058

Praise:

inquiry KCD2-UT2-Ex1 通用温度转换器现货供应
倍加福通用温度转换器KCD2-UT2-Ex1现货供应
KCD2-UT2-Ex1
产品特点
       ▷ 1通道隔离栅
       ▷ 24 V DC电源(电源导轨)
       ▷ 热电偶,RTD,电位计或电压输入
       ▷ 电流输出0/4 mA ... 20 mA
       ▷ 接收器或源模式
       ▷ 可通过PACTware配置
       ▷ 线路故障(LFD)和传感器断线检测
       ▷ 符合SIL 2标准 符合IEC 61508 / IEC 61511

产品介绍
Current output 0/4 mA ... 20 mA
General specifications
Signal type Analog input
Functional safety related parameters
Safety Integrity Level (SIL) SIL 2
Supply
Connection terminals 9+, 10- or power feed module/Power Rail
Rated voltage 19 ... 30 V DC
Ripple within the supply tolerance
Power dissipation/power consumption ≤ 0.98 W / 0.98 W
Interface
Programming interface programming socket
Input
Connection side field side
Connection terminals 1, 2, 3, 4
RTD type Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995)
type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94)
type Cu10, Cu50, Cu100 (P50353-92)
type Ni100 (DIN 43760)
  Measuring current approx. 200 µA with RTD
  Types of measuring 2-, 3-, 4-wire connection
  Lead resistance max. 50 Ω per line
  Measurement loop monitoring sensor breakage, sensor short-circuit
Thermocouples type B, E, J, K, N, R, S, T (IEC 584-1: 1995)
type L (DIN 43710: 1985)
type TXK, TXKH, TXA (P8.585-2001)
  Cold junction compensation external and internal
  Measurement loop monitoring sensor breakage
Potentiometer 0 ... 20 kΩ (2-wire connection), 0.8 ... 20 kΩ (3-wire connection)
Voltage selectable within the range -100 ... 100 mV
Input resistance ≥ 1 MΩ (-100 ... 100 mV)
Output
Connection side control side
Connection terminal 5: source (-), terminal 6: source (+), terminal 7: sink(-), terminal 8: sink (+)
Output Analog current output
  Current range 0 ... 20 mA or 4 ... 20 mA
  Fault signal downscale 0 or 2 mA, upscale 21.5 mA (acc. NAMUR NE43)
  Source load 0 ... 550 Ω
open-circuit voltage ≤ 18 V
  Sink Voltage across terminals 5 ... 30 V. If the current is supplied from a source > 16.5 V,
series resistance of ≥ (V - 16.5)/0.0215 Ω is needed, where V is the source voltage.
The maximum value of the resistance is (V - 5)/0.0215 Ω.
Transfer characteristics
Deviation  
  After calibration Pt100: ± (0.06 % of measurement value in K + 0.1 % of span + 0.1 K (4-wire connection))
thermocouple: ± (0.05 % of measurement value in °C + 0.1 % of span + 1.5 K (1.7 K for types R and S))
this includes ± 1.3 K error of the cold junction compensation
mV: ± (50 µV + 0.1 % of span)
potentiometer: ± (0.05 % of full scale + 0.1 % of span, (excludes errors due to lead resistance))
  Influence of ambient temperature deviation of CJC included:
Pt100: ± (0.0015 % of measurement value in K + 0.006 % of span)/K ΔTamb*)
thermocouple: ± (0.02 K + 0.005 % of measurement value in °C + 0.006 % of span)/K ΔTamb*)
mV: ± (0.01 % of measurement value + 0.006 % of span)/K ΔTamb*)
potentiometer: ± 0.006 % of span/K ΔTamb*)
*) ΔTamb = ambient temperature change referenced to 23 °C (296 K)
  Influence of supply voltage < 0.01 % of span
  Influence of load ≤ 0.001 % of output value per 100 Ω
Reaction time worst case value (sensor breakage and/or sensor short circuit detection enabled)
mV: 1 s, thermocouples with CJC: 1.1 s, thermocouples with fixed reference temperature: 1.1 s, 3- or 4-wire RTD: 920 ms, 2-wire RTD: 800 ms, Potentiometer: 2.05 s
Galvanic isolation
Output/supply, programming input functional insulation, rated insulation voltage 50 V AC
There is no electrical isolation between the programming input and the supply.
The programming cable provides galvanic isolation so that ground loops are avoided.
Indicators/settings
Display elements LEDs
Configuration via PACTware
Labeling space for labeling at the front
Directive conformity
Electromagnetic compatibility  
  Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibility NE 21:2012
EN 61326-3-2:2008
Degree of protection IEC 60529:2001
Protection against electrical shock UL 61010-1:2004
Ambient conditions
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protection IP20
Connection screw terminals
Mass approx. 100 g
Dimensions 12.5 x 114 x 124 mm (0.5 x 4.5 x 4.9 inch) , housing type A2
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
EU-type examination certificate BASEEFA 13 ATEX 0102 X
  Marking Ex-Hexagon II (1)G [Ex ia Ga] IIC , Ex-Hexagon II (1)D [Ex ia Da] IIIC , Ex-Hexagon I (M1) [Ex ia Ma] I
  Input [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Inputs terminals 1, 2, 3, 4
  Voltage Uo 9 V
  Current Io 13.1 mA
  Power Po 30 mW
Analog outputs, power supply, collective error  
  Maximum safe voltage 250 V (Attention! This is not the rated voltage.)
Interface  
  Maximum safe voltage 250 V (Attention! The rated voltage is lower.), RS 232
Certificate BASEEFA 13 ATEX 0103 X
  Marking Ex-Hexagon II 3G Ex nA II T4 Gc [device in zone 2]
Galvanic isolation  
  Input/Other circuits safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity  
  Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
UL approval  
  Control drawing 116-0379 (cULus)
IECEx approval IECEx BAS 13.0057X
  Approved for [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
General information
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable.

Fuxb automation will serve you wholeheartedly,Tel: +86-021-51601058      phone:+86-189-6426-6865
Products can be applied to
Fuxb automation is your choice!
Fuxb automation staff sincerely look forward to your visit   Tel: +86-021-51601058      +86-189-6426-6865